学科分类
/ 1
3 个结果
  • 简介:目的分析耳鼻喉科门诊耳呜病例的临床特点。方法对2009年12月~2010年7月在本科门诊就诊的2408例患者进行耳鸣问卷调查,将获得的数据进行统计学分析。结果2408例患者中,年龄6—95岁,平均(47.02±17.05)岁。确诊的耳鸣患者共996例,其中男性388例(38.96%)、女性608例(61.04%),男女耳鸣发生率差异有统计学意义(P=0.0019)。排除4例12岁以下患者,将其余992例患者,根据耳鸣对生活影响的轻重分为4类:无影响149例(占15.02%)、轻度影响480例(占48.39%)、中度影响329例(33.16%)、重度影响34例(3.43%),对生活影响的轻重程度与就诊的关系存在显著相关性(P〈0.0001)。耳鸣持续时间与单双耳发病两者之间存在显著相关性(P〈0.0001)。随机询问44例耳呜患者,发现治疗时间〈1个月者,有效10例、无效14例;1—2个月者,有效6例;〉2个月者,有效8例、无效6例。结论耳鸣的发生率在耳鼻喉科门诊患者中所占比例极高,其中尤以女性多见。双侧耳鸣持续时间更长。随着治疗时间的延长,有效率有增加趋势。(中国眼耳鼻喉科杂志,2013,13:173—175)

  • 标签: 耳鸣 门诊患者 调查
  • 简介:AIM:Tomeasurecentralcornealthickness(CCT)andpre-cornealtearfilmthicknessusingtheGalileidualScheimpfluganalyzer(GSA)inNewZealandWhiterabbits.METHODS:TennormalNewZealandWhiterabbits(20eyes)wereincludedinthisstudy.Withtheassistanceof0.1%fluorescein,thepre-cornealtearfilmcanbewellvisualized.BotheyesofeachrabbitwerescannedoncewiththeGSApre-andpost-instillationof1μL0.1%fluorescein.ThedifferencebetweenthetwomeasurementsofCCT(4-mmdiameter)wasrecordedasthepachymetricvaluesofthecentraltearfilm.RESULTS:TheCCTofpre-andpost-instillationwas388.8±9.5μmand407.0±10.5μm,respectively.Afterapairedt-testanalysis,thecentralpre-cornealtearfilmthicknessof4mmdiameterwas18.2±5.31μmwitha95%confidenceintervalof(15.7,20.6)μm(P<0.001).CONCLUSION:GSAcanbeusedtomeasureCCTandanalyzecentraltearfilmthicknessofrabbitswiththehelpoffluorescein.

  • 标签: TEAR film SCHEIMPFLUG rabbits central CORNEAL
  • 简介:AIM:Toevaluatetheaccuracyofsphericalequivalent(SE)estimatesofadouble-passsystemandtocompareitwithretinoscopy,subjectiverefractionandatablemountedautorefractor.METHODS:Non-cycloplegicrefractionwasperformedon125eyesof65healthyadults(age23.5±3.0years)fromOctober2010toJanuary2011usingretinoscopy,subjectiverefraction,autorefraction(AutokeratorefractometerTOPCONKR-8100,Japan)andadoublepasssystem(OpticalQualityAnalysisSystem,OQAS,VisiometricsS.L.,Spain).Nineconsecutivemeasurementswiththedouble-passsystemwereperformedonasubgroupof22eyestoassessrepeatability.ToevaluatethetruenessoftheOQASinstrument,theSElaboratorybiasbetweenthedoublepasssystemandtheothertechniqueswascalculated.RESULTS:TheSEmeancoefficientofrepeatabilityobtainedwas0.22D.SignificantcorrelationscouldbeestablishedbetweentheOQASandtheSEobtainedwithretinoscopy(r=0.956,P<0.001),subjectiverefraction(r=0.955,P<0.001)andautorefraction(r=0.957,P<0.001).ThedifferencesinSEbetweenthedouble-passsystemandtheothertechniquesweresignificant(P<0.001),butlackedclinicalrelevanceexceptforretinoscopy;Retinoscopygavemorehyperopicvaluesthanthedouble-passsystem-0.51±0.50Daswellasthesubjectiverefraction-0.23±0.50D;Moremyopicvalueswereachievedbymeansofautorefraction0.24±0.49D.CONCLUSION:Thedouble-passsystemprovidesaccurateandreliableestimatesoftheSEthatcanbeusedforclinicalstudies.Thistechniquecandeterminethecorrectfocuspositiontoassesstheocularopticalquality.However,ithasarelativelysmallmeasuringrangeincomparisonwithautorefractors(-8.00to+5.00D),andrequirespriorinformationontherefractivestateofthepatient.

  • 标签: DOUBLE-PASS system optical quality RETINOSCOPY autorefraction