学科分类
/ 25
500 个结果
  • 简介:摘要目的在国内建立胰岛素自身抗体(IAA)的电化发光检测,并初步评价其应用价值。方法胰岛素原采用磺基吡啶钌衍生物(Sulfo-tag)和生物素标记后,与血清IAA孵育结合。Meso Scale Discovery(MSD)链霉亲和素电化发光平板捕获标记的抗原抗体复合物后,采用MSD电化发光仪进行检测,以IAA指数≥0.005作为阳性阈值。通过优化检测条件后,采用微量平板放射免疫比较两种方法的相关性和一致性。选取2016至2018年于中南大学湘雅二医院代谢内分泌科门诊或住院的新诊断1型糖尿病(T1DM)患者(55例)及其一级亲属(216名),以及健康志愿者(健康对照组,413名)为研究对象,检测其血清样本,初步评价电化发光检测IAA的临床应用价值。结果优化条件包括:(1)生物素标记的胰岛素原和磺基吡啶钌衍生物标记的胰岛素原的最适浓度均为800 ng/ml;(2)酸化血清的方式为水浴30℃静置孵育45 min;(3)在反应体系中先加入35 μl稀释后的抗原,再加入15 μl Tris-HCl缓冲液,然后与酸化血清混匀孵育过夜能获得更高的信噪比(S/N)。电化发光间隔3个月重复检测22例样本,IAA指数差异无统计学意义(P=0.095),阴/阳性判定完全一致;与微量平板放射免疫检测IAA的一致率为93.7%(119/127)(Kappa值为0.858),指数呈正相关(相关系数r=0.749,P<0.001)。电化发光受试者工作特征(ROC)曲线下面积(AUC)为0.764(95%CI:0.669~0.858)。电化发光检测T1DM患者IAA的阳性率为52.73%(29/55),明显高于健康对照组的0.76%(2/263)(P<0.001);检测T1DM一级亲属组的阳性率为0.93%(2/216),与健康对照组相比差异无统计学意义(P=0.854)。结论电化发光检测IAA有较高的灵敏度和特异度,操作简便无放射污染,具有很好的临床应用价值。

  • 标签: 糖尿病,1型 胰岛素自身抗体 电化学发光法
  • 简介:摘要目的开发建立新型高敏锌转运体8自身抗体(ZnT8A)电化发光检测(ECL-ZnT8A),并初步评价其临床应用价值。方法选择自2016年1月至2019年12月就诊于南京医科大学第一附属医院的1型糖尿病(T1DM)患者100例、2型糖尿病(T2DM)患者150例、健康对照者360例(158例用于方法的建立,202例用于方法灵敏度和特异度的鉴定)进行ECL-ZnT8A检测,120例(60例健康对照,50例T1DM,10例ZnT8A阳性血清)同时检测ECL-ZnT8A和放射免疫沉淀(RBA)-ZnT8A。经t检验、单因素方差分析和χ²检验比较各组间ZnT8A指数和阳性率的差异。结果(1)400 ng/ml的ZnT8-Biotin和200 ng/ml的ZnT8-Sulfo-TAG是ECL-ZnT8A反应体系的最适浓度。(2)ECL-ZnT8A批内变异系数为3.4%~8.2%,批间变异系数为10.5%~12.8%,阴、阳性结果判断重复性100%。(3)ECL-ZnT8具有较高的灵敏度(97.7%)和特异度(96.1%),与RBA-ZnT8A的一致率为96.70%(116/120,Kappa值为0.929),指数呈显著正相关(r=0.806,P<0.01)。(4)T1DM患者ECL-ZnT8A阳性率为52.00%(52/100),显著高于健康对照组的0.99%(2/202)(χ²=118.528,P<0.01)和T2DM组的1.33%(2/150),差异具有统计学意义(χ²=90.955,P<0.01)。结论ECL-ZnT8A检测操作简便无放射污染,具有很好的临床应用价值。

  • 标签: 糖尿病,1型 锌转运体 8自身抗体 胰岛自身抗体 电化学发光法
  • 简介:【摘要】 目的 电化发光免疫分析技术在临床检验中的效果评价。方法 在 2018年 1月 -2019年 1月到院治疗的患者中随机抽出 86例,随机均分为参照组和观察组,各 43例。参照组用酶联免疫吸附,观察组用电化发光免疫分析技术,对比血清中肿瘤标记物、检查正确率。结果 检测后,参照组血清中肿瘤标记物不如观察组明显,数据不突出;观察组检查正确率更高,( P< 0.05)统计学意义明显。结论 电化发光免疫分析技术可提高临床检验中的正确性,数据更准确,应推广。

  • 标签: 电学 免疫 血清
  • 简介:【摘要】目的 探究分析电化发光免疫分析技术在乙型肝炎病毒临床检验中的临床价值。方法 选取我院 2018年 4月 -2019年 4月收治的乙肝患者共 84例,依托于数据表,将患者分为两组,每组各 42例患者。期间,参照组采取酶联免疫分析( ELISA),实验组则采用电化发光免疫分析,进而对两种检验方法的准确性进行考量比对。结果 其中,实验组的检验准确率为 92.86%,参照组的准确率为 71.43%,实验组患者的检验准确率显著优于参照组,该差异存在统计学意义( P< 0.05)。结论 在临床上对乙肝患者进行检验的过程中,适时的引入电化发光免疫分析技术进行检测,可以显著提升乙肝检测的准确率,从而助力乙肝患者的早发现、早治疗。可见,该种检测方法在临床上有着很大的推广价值。

  • 标签: 电化学发光免疫分析 乙型肝炎病毒 临床检验
  • 简介:摘要目的:在临床检验中应用化学发光免疫分析有哪些效果。方法:选取 2019年 1月至 2020年 1月在我血站进行检验的患者 100人。对患者应用化学发光免疫分析检测为实验组,对患者应用放射免疫检测为对照组。对比两组患者的 FT4(游离甲状腺素)、 FT3(游离三碘甲状腺原氨酸)、 TSH(甲状腺刺激激素)、 TT3(总三碘甲状腺原氨酸)、 TT4(总甲状腺素)检出率,对甲状腺疾病患者的检测结果进行分析。 结果:实验组患者FT4的检出率为 100%、 FT3的检出率为 100%、 TSH的检出率为 98%、 TT3的检出率为 98%,TT4;对照组 FT4的检出率为 92%、 FT3的检出率为 92%、 TSH的检出率为 90%、 TT3的检出率为 90%。实验组的检出率明显高于对照组( P<0.05)。结论:在甲状腺疾病的临床体验中应用化学发光免疫分析对甲状腺疾病有极高的敏感度、特异度,可以提高检验的准确性,为治疗疾病提供依据,值得在临床上进一步推广。

  • 标签: 甲状腺疾病 化学发光免疫分析分 临床检验
  • 简介:【摘要】目的:探析甲状腺疾病应用化学发光免疫分析进行临床检验的应用价值。方法:入选时间为2019年7月~2020年7月,选择我院收入的甲状腺疾病患者70例作为观察组,并选择70例健康志愿者作为对照组,应用化学发光免疫分析进行检测,对比观察FT3、FT4、Tg、TSH等指标。结果:观察组FT4、FT3、Tg指标水平高于对照组(P

  • 标签: 甲状腺 化学发光免疫分析 临床检验
  • 简介:摘要:近年来,经济快速发展,人们的生活水平不断提高,国民食品安全意识得以强化,但国民生活质量提升后,市场中食品的生产、组成结构不断变化。在食品生产行业多元化发展中,食品安全问题发生率明显提高。为加大食品安全管理力度、减少食品安全事故,需重视食品安全检测技术的推广与应用。在此背景下,以电化分析为例,对食品安全问题成因及检测现状展开分析。同时,对伏安分析、电位分析电化分析的应用进行简单研究,以明确电化分析测定食品安全质量的基本价值。

  • 标签: 电化学分析法 食品安全 检测 应用分析
  • 简介:摘要: 目的: 比较电化发光免疫 (ECLIA) 与酶联免疫吸附 (ELISA) 检测艾滋病病毒 (HIV) 抗体的效果。 方法:选取 320例高危 HIV血液样本,均经 CLIA、 ELISA检测,将 HIV确认中心检测结果作为金标准,对比两种检测方式的临床价值。结果: 320 例高危 HIV 血液样本中 HIV 抗体阳性 9 例,阳性率为 2.81 %;在 9 例 HIV 抗体阳性血液样本中, CLIA 检测阳性 8 例, ELISA 检测阳性 7 例;在 311 例 HIV 抗体阴性血液样本中, CLIA 检测阴性 298 例, ELISA 检测阴性 296 例; CLIA 的灵敏度、准确度、特异度高于 ELISA 。 结论:在 HIV 抗体检测中 CLIA 灵敏度、准确度、特异度高于 ELISA ,具有较高的诊断价值。

  • 标签: 电化学发光免疫法 艾滋病 酶联免疫吸附法
  • 简介:【摘要】目的 研究临床检验中电化发光免疫分析技术的应用可行性及有效性。方法 80例 入组对象均筛选自本院收治的甲状腺肿瘤患者,研究时间选取2019年 3月 -2020年 3月,随机分组,对照组( 40例)应用放射免疫分析,观察组( 40例)选择 化学发光免疫诊断,对比诊断的准确度。结果 观察组检验的准确度高于对照组,组间对比,存在统计学意义(P<0.05)。 结论 化学发光免疫在临床检验中,准确度较高,优势明显,降低诊断失误出现的可能性,要重视。

  • 标签: 化学发光免疫 临床检验 可行性 有效性
  • 简介:  【摘 要】目的:研究比较艾滋病抗体检测采用化学发光免疫分析与酶免疫的结果。方法:以 2018年 9月 -2019年 9月本地区抽查的 1258例艾滋病高危人群作为研究对象,对采集的血清样本进行化学发光免疫分析与酶免疫检测,完成检测后对血液样本实施蛋白免疫印迹检测,研究比较两种检测方法的准确性。结果:化学发光免疫分析阳性率、灵敏度、特异性等指标高于酶免疫,两种检测方法无统计差异( P>0.05)。结论:化学发光免疫分析与酶免疫均可有效检测艾滋病抗体,化学发光免疫分析阳性率、灵敏度、特异性等指标高于酶免疫,值得临床推广应用。    【关键词】化学发光免疫分析 ;酶免疫 ;艾滋病抗体     [Abstract] Objective: To compare the results of chemiluminescence immunoassay and enzyme immunoassay in HIV antibody detection. Methods: 1258 HIV high-risk groups in our region from September 2018 to September 2019 were selected as the research objects. The serum samples were detected by chemiluminescence immunoassay and enzyme immunoassay. After the detection, the blood samples were detected by Western blot, and the accuracy of the two detection methods was compared. Results: the positive rate, sensitivity and specificity of chemiluminescence immunoassay were higher than those of enzyme immunoassay. There was no statistical difference between the two methods (P > 0.05). Conclusion: both chemiluminescence immunoassay and enzyme immunoassay can detect HIV antibody effectively. The positive rate, sensitivity and specificity of chemiluminescence immunoassay are higher than those of enzyme immunoassay, which is worthy of clinical application.

  • 标签:
  • 简介:【摘要】 目的 探讨电化发光免疫( ECLIA)检测梅毒螺旋体 (TP)特异性抗体的系统性能和临床价值 。方法 研究开展时间为2019年 9月 -2020年 1月, 选取129例高危 梅毒螺旋体(TP)特异性抗体阳性 患者(观察组)以及120例健康体检者(对比组)进行研究。受检者均采用 电化发光免疫进行检测,并将检验结果与金标准进行对比,观察其应用价值。结果 金标准诊断TP特异性抗体阳性 50例,占比 38.76%,阴性 78例,占比 60.47%。 对比组

  • 标签:
  • 简介:摘要微阵列蛋白芯片是研究蛋白质与蛋白质相互作用和识别疾病相关自身抗原的平台,也可以高通量的形式检测抗原与抗体之间免疫结合反应。该方法是一种微型化的固相免疫检测方法,在肿瘤、感染性疾病、自身免疫性疾病及变态反应性疾病的筛查、辅助诊断和治疗监测中逐渐得到临床认可。该共识对以平面基质为载体,采用化学发光检测的蛋白芯片的临床应用进行规范化和标准化。

  • 标签: 蛋白质阵列分析 微阵列蛋白芯片 固相免疫 高通量 化学发光法
  • 简介:摘要:物理化学作为一门研究所有物质体系的化学行为的原理、规律和方法的学科,其基本原理和研究方法在高中化学教学中有着非常重要的指导作用。本论文主要探究物理化学知识体系中与中职电化教学相关的内容,对电化教学中理化知识结合的方法做了详细介绍,希望可以促进电化教学水平的提升和教学效果的增强。

  • 标签: 物理化学知识 电化学 教学
  • 简介:摘要:据联合国艾滋病规划署调查显示:从2013年末到2018年末艾滋病人数由3430万人增加到3790万人,携带者的数量呈现逐年上升的趋势,而我国的艾滋病例从2013年的80.9万人增至2018年末的125万人,截止到2019年末,全国报告存活的感染者有95.89万人。针对目前艾滋病的传播进行研究,主要表现为性传播,其他传播的途径已经基本阻断或是得到了有效的控制。如何早期诊断并发现人类免疫缺陷病毒的感染成为了当前亟待解决的问题。

  • 标签: 化学发光法 免疫印迹 人类免疫缺陷病毒
  • 简介:【摘要】目的 研究将化学发光免疫分析应用在临床检验中的效果 。 方法 将本院自 2019 年 6 月 ~2020 年 6 月的 68 例甲状腺肿瘤患者利用抓小球的方式进行分组,每组 34 例。给予参照组放射免疫检验,给予治疗组化学发光免疫检验,对比两组患者检验准确率和误诊率。 结果 治疗组甲状腺蛋白水平明显高于参照组( P < 0.05 );治疗组疾病检验准确率为 97.06% ,误诊率为 2.94% ,明显优于参照组( P < 0.05 )。 结论 在临床检验中应用化学发光免疫分析,可以得到良好的检验效果,检测准确率较高,能够为临床诊断与治疗提供有利参考数据,值得推广和应用 。

  • 标签: 临床检验 化学发光免疫分析 应用效果
  • 简介:摘要目的测定山东东阿县原发性醛固酮增多症(primary aldosteronism,PA)的醛固酮与肾素比值(aldosterone to renin ratio,ARR)的分界值。方法选取2017年1月至12月于本院临床中心登记的146例患者,其中51例为PA,95例为原发性高血压(essential hypertension,EH),对患者的右肾上腺进行CT扫描和病理切片检查,检测所有患者的血液参数,包括甲状旁腺素、血浆醛固酮浓度等,进行单因素分析和二元逻辑回归模型;绘制ROC曲线,确定ARR的最大敏感性和特异性。结果PA组的年龄低于EH组(P<0.05)。而且PA组和EH组的甲状旁腺(PTH)相比[(43.08±19.16)pg/ml比(55.71±18.66)pg/ml],差异有统计学意义(P=0.033);伴有高排泄的醛固酮PA患者有更高的血浆醛固酮浓度(PAC)和更低血浆肾素浓度(PRC),分别为578.7 ng/dl比418.1 ng/dl,6.5 ng/dl比13.0 ng/dl。单因素分析发现年龄、PTH、PRC、PAC作为连续性变量与ARR相关;二元逻辑回归模型分析发现,上述因素为独立预测因子,ARR和PAC的95%置信区间分别是(-119.70,-51.75)和(-215.15,-73.00);ARR曲线下面积为0.984,PA和EH的分界值为43.6,具有高敏感性(96.1%)和特异性(91.6%)。结论本研究为PA的诊断提供精确分界值,对指导山东省东阿县的PA进行早期筛选具有重要意义。

  • 标签: 原发性醛固酮增多症 醛固酮 肾素 分界值
  • 简介:摘要: 顺应教育改革的潮流,高中化学也进行了一定的整改。当代高考电化的考查从从前的理论化向生活实用转型。高中化学中的电化本身就是抽象的学问,许多高中生在学习电化时都产生了学习困难,因此教师在进行电化教学时要调整教学策略,找出适合高中学生的电化教学策略。本文在明确电化概念的基础上对高中化学电化教学策略进行探究,对高中化学教学提供一定的方向。

  • 标签: 高中化学 电化学 教学
  • 简介:摘要:化学学科中电化是很重要的分支,高中化学需要学习电化基础知识。学习过程中如果可以准确掌握电化的基础知识,了解这部分知识的应用,更好的完成化学知识学习。通过分析电化内涵,结合自身学习经验分析高中化学电化基础的应用。

  • 标签: 高中化学 电化学基础 具体应用
  • 简介:摘要:孩子成⻓发展道路上,高中学习起到决定性的作用,其中高中化学是一 ⻔以实验为依据的重要学科,与生产生活化学密切相关,其中电化这部分内 容更能体现微观与宏观辨识力的核心科学素养,也是高考试题的必考内容,所 以提高学生对电化的学习兴趣及改变授课方式很重要。在本文中针对高中电 化学教学问题进行分析研究,并提出策略。

  • 标签: 高中 电化学 电极反应 放电顺序
  • 简介:摘要:目的 采用化学发光原理,初步建立心型脂肪酸结合蛋白检测试剂盒的方法学评价。 方法 用化学发光在安图化学发光免疫分析仪上测定心型脂肪酸结合蛋白,依据 CLSI EP 文件对该方法精密度、准确度、线性、干扰进行评估并与朗道免疫比浊试剂进行方法学比对。 结果: 该方法的批内和批间精密度均小于 5% ;在 1.87ng/ml ~ 146.47ng/ml 范围内,线性良好,线性相关方程为 y=0.9751x-0.4516, R 2 =0.9993 ;临床样本平均回收率为 95.2% ; 500mg/dL 血红蛋白、 500mg/dL 甘油三酯、 30mg/dL 胆红素对于 H-FABP 检测无干扰;与朗道免疫比浊试剂进行方法学比较,回归方程为: y=1.0018x-0.0863 , R 2 = 0.9881 ,两者相关性较好。 结论 使用化学发光法测定心型脂肪酸结合蛋白,结果准确,线性范围宽,重复性好,与进口朗道试剂相关性好,能够满足临床使用需求。

  • 标签: 心型脂肪酸结合蛋白 化学发光法 方法学评价